Solax Forth series 3 Phase 9 MPPT 100KW
Marcă: | |
Unitate: | pcs |
Cod: | INV-SLX-X3-FTH-100K |
Garanție: | 5 an |
DC INPUT | |
Max. PV array input power [kWp] | 150 |
Max. PV input voltage [V] | 1100 |
Nominal input voltage [V] | 580/600 |
Startup voltage [V] | 200 |
MPP tracker voltage range [V] | 180-1000 |
No. of MPP trackers | 9 |
Strings per MPP tracker | 2 |
Max. PV input current per MPPT [A] | 32 |
Isc PV Array Short Circuit current per MPPT [A] | 46 |
AC OUTPUT | |
Rated AC output power [kW] | 100 |
Rated AC output current [A] | 151.6/145 |
Max. AC output apparent power [kVA] | 110 |
Max. AC output current [A] | 166.7/159.5 |
Nominal AC voltage [V] | 220/380, 230/400, 3/N/PE, 3/PE |
AC voltage range [V] | 304 ~ 480 |
Nominal AC frequency/AC frequency range [Hz] | 50/60; ±5 |
THDi (Rated power) [%] | <3 |
Power Factor range | 0.8 leading ~ 0.8 lagging |
SYSTEM DATA | |
MPPT eciency [%] | 99.9 |
Max. eciency [%] | 98.6 |
Ingress protection | IP66 |
Operating ambient temperature range [°C] | -30~+60 (Derating above 45) |
Max. operation altitude [m] | 4000 (Derating above 3000) |
Relative humidity [%] | 0~100 |
Dimensions [W×H×D] [mm] | 985×660×327.5 |
Weight [kg] | 83 |
Cooling concept | Smart fan cooling |
Communication interfaces | RS485 / USB / DRM / PLC(Optional) |
Optional monitoring dongle | Pocket WiFi/LAN/4G |
Display | LCD(16x2, optional)/LEDx4 |
PROTECTION | |
Over/under voltage protection | YES |
DC isolation protection | YES |
Grid monitoring | YES |
DC injection monitoring | YES |
Residual current detection | YES |
Anti-islanding protection | YES |
String fault detection | YES |
SPD (DC/AC) | Type II / Type II |
Arc-fault circuit interrupter(AFCI) | Optional |
AC terminals over temperature detection | YES |
AC auxiliary power supply(APS) | Optional |
Power line communication(PLC) | Optional |
STANDARD | |
Safety | IEC/EN 62109-1; IEC/EN 62109-2; NB/T 32004 |
EMC | IEC/EN 61000; NB/T 32004 |
Certification | EN 50549; AS4777.2; VDE4105; IEC 61727; IEC 62116; IEC 61683; IEC 60068; EN 50530; NB/T 32004 |