SUN 2000-50KTL-M3
3 phase inverter (30-50KTL M3 series)
Optimization - partial or full, with 450W optimizers,
Flexible string design
Flexible communication - WLAN, Fast Ethernet, 4G, RS485
5-year warranty - extendable to 20 years
Up to 30-50 kW, 4 working points
Marka: | |
Jedinica: | pcs |
Kod: | INV-HUA-50KTL-M3 |
Garancija: | 5 godina |
3-phase inverters (30-40KTL M3 series)
Optimization - partial or full, with 450W optimizers,
AI BOOST active safety - Artificial Intelligence assisted active arc fault protection
Higher yield - Up to 30% higher energy yield with optimizer (450Wp)3
Flexible string design
Flexible communication - WLAN, Fast Ethernet, 4G, RS485
5-year warranty - extendable to 20 years
Up to 30-50 kW, 4 working points
TÜV certified, both outdoor and indoor
Maximum inverter input power per input
10,000Wp if designed with long strings and all solar panels are equipped with SUN2000-450W-P optimizer
Product benefits:
- Built-in PID recovery
- Built-in surge protection (AC, DC)
- P.C./P.C.protection
- Radiofrequency control
- 4 operating points, and 8 inputs in total
Efficiency | |
Max. Efficiency | 98.5% |
European Efficiency | 98.0% |
Input | |
Max. Input Voltage | 1,100 V |
Max. Current per MPPT | 30 A |
Max. Current per Input | 20A |
Max. Short Circuit Current per MPPT | 40A |
Start Voltage | 200V |
MPPT Operating Voltage Range | 200 V ~ 1000 V |
Rated Input Voltage | 600 V |
Number of Inputs | 8 |
Number of MPP Trackers | 4 |
Output | |
Rated AC Active Power | 50,000W |
Max. AC Apparent Power | 55,000 VA |
Max. AC Active Power (cosφ=1) | 55,000 W |
Rated Output Voltage | 400 Vac / 480 Vac, 3W+(N)+PE |
Rated AC Grid Frequency | 50 Hz / 60 Hz |
Rated Output Current | 72.2 A @ 400Vac, 60.1 A @ 480Vac |
Max. Output Current | 79.8 A @ 400Vac, 66.5 A @ 480Vac |
Adjustable Power Factor Range | 0.8 LG ... 0.8 LD |
Max. Total Harmonic Distortion | < 3% |
Protection | |
Input-side Disconnection Device | Yes |
Anti-islanding Protection | Yes |
AC Overcurrent Protection | Yes |
DC Reverse-polarity Protection | Yes |
PV-array String Fault Monitoring | Yes |
DC Surge Arrester | Type II |
AC Surge Arrester | Type II |
DC Insulation Resistance Detection | Yes |
Residual Current Monitoring Unit | Yes |
Arc Fault Protection | Yes |
Ripple Receiver Control | Yes |
Integrated PID Recovery | Yes |
Communication | |
Display | LED Indicators, Bluetooth + APP |
RS485 | Yes |
Smart Dongle |
WLAN/Ethernet via Smart Dongle-WLAN-FE (Optional) 4G / 3G / 2G via Smart Dongle-4G (Optional) |
Monitoring BUS (MBUS) | Yes (Isolation Transformer required) |
Optimizer Compatibility | |
DC MBUS Compatible Optimizer | MERC-1100/1300W-P |
General Data | |
Dimensions (W x H x D) | 640 x 530 x 270 mm (25.2 x 20.9 x 10.6 inch) |
Weight (with mounting plate) | 49 kg (108.1 lb) |
Operating Temperature Range | -25 ~ + 60 °C (-13 °F ~ 140 °F) |
Cooling Method | Smart Air Cooling |
Max. Operating Altitude | 4,000 m (13,123 ft.) |
Relative Humidity | 0% RH ~ 100% RH |
DC Connector | Amphenol HH4 |
AC Connector | Waterproof Connector + OT/DT Terminal |
Protection Degree | IP66 |
Topology | Transformerless |
Nightime Power Consumption | ≤ 5.5W |
Optimizer Compatibility | |
DC MBUS Compatible Optimizer | SUN2000-450W-P |
Standard Compliance (more available upon request) | |
Safety | EN 62109-1/-2, IEC 62109-1/-2, EN 50530, IEC 62116, IEC 60068, IEC 61683 |
Grid Connection Standards | EC 61727, VDE-AR-N4105, VDE 0126-1-1, BDEW, G59/3, UTE C 15-712-1, CEI 0-16, CEI 0-21, RD 661, RD 1699, P.O. 12.3,RD 413, EN-50438-Turkey, EN-50438-Ireland, C10/11, MEA, Resolution No.7, NRS 097-2-1, AS/NZS 4777.2, DEWA |