Output |
Rated AC Power Output |
6000 VA |
Maximum AC Power Output |
6000 VA |
AC Output Voltage - Line to Line / Line to Neutral (Nominal) |
380 / 220; 400 / 230 Vac |
AC Output Voltage - Line to Neutral Range |
184 – 264.5 Vac |
AC Frequency |
50/60 ± 5 Hz |
Maximum Continuous Output Current (per Phase) |
10 A |
Grids Supported - Three Phase |
3 / N / PE (WYE with Neutral) |
Utility Monitoring, Islanding Protection, Configurable Power Factor, Country Configurable Thresholds |
Yes |
INPUT |
Maximum DC Power (Module STC) |
9000 W |
Transformer-less, Ungrounded |
Yes |
Maximum Input Voltage |
900 Vdc |
Nominal DC Input Voltage |
750 Vdc |
Maximum Input Current |
10 Adc |
Reverse-Polarity Protection |
Yes |
Ground-Fault Isolation Detection |
700kΩ Sensitivity |
Maximum Inverter Efficiency |
98% |
European Weighted Efficiency |
97.3% |
Nighttime Power Consumption |
< 2.5 W |
ADDITIONAL FEATURES |
Supported Communication Interfaces |
RS485, Ethernet, wireless SolarEdge Home Network (optional)(6), Wi-Fi (optional), Cellular (optional) |
Smart Energy Management |
Export Limitation, Home Energy Management (Device Control) |
Inverter Commissioning |
With the SetApp mobile application using built-in Wi-Fi access point for local connection |
Arc Fault Protection |
Integrated, user configurable (according to UL 1699B) |
STANDARD COMPLIANCE |
Safety |
IEC 62109-1/2 |
Grid Connection Standards |
VDE-AR-N 4105, Tor Erzeuger Typ A, EN 50549-1, CEI 0-21, G98 Type A, G98 NI Type A, G100, RD1699 / RD413 / NTS, VDE-V 0126-1-1, VFR 2019, C10/11, EN 50438 |
Electromagnetic Compatibility (EMC) |
IEC 61000-6-2, IEC 61000-6-3, IEC 61000-3-11, IEC 61000-3-12, EN 55011 |
RoHS |
Yes |
INSTALLATION SPECIFICATIONS |
AC Output |
Cable Gland – diameter 15 – 21 mm |
DC Input |
2 MC4 pairs |
Dimensions (H x W x D) |
540 x 315 x 191mm |
Weight |
16.4 kg |
Operating Temperature Range |
-40 to +60 ̊C |
Cooling |
Internal Fan |
Noise |
< 40 dBA |
Protection Rating |
IP65 – outdoor and Indoor |
Mounting |
Bracket Provided
|