Dyness 10 kW D10K-HT-A Hybrid HV 3-Phase Inverter
The HT-A series is Dyness’s three-phase, high-voltage hybrid inverter. This unit is the inverter itself: it manages solar power generation, the charging and discharging of the high-voltage battery, grid feeding, and backup operation. The battery is a separate product; the system accommodates a 120–750 V HV storage unit with a nominal voltage of 600 V.
The 10-kW version is the mid-range model in the series (5 / 6 / 8 / 10 / 12 / 15 kW), featuring a 20-kW PV input and three independent MPPT trackers, typically suited for a roof system of around 15–20 kWp.
What is it used for?
Larger single-family homes, villas, or smaller commercial sites with three-phase wiring. A typical configuration includes 15–20 kWp of PV and 15–30 kWh of storage capacity.
This is ideal when the load side includes a heat pump, air conditioning, electric cooking, and an EV charger. Thanks to the 10 kW backup output and the 18 kVA one-minute peak, high-inrush-current loads—such as a deep-well pump or compressor—can also be started in off-grid mode.
A particular strength is the asymmetric output per phase: each phase can be loaded up to 50% of the nominal power—meaning, for the 10 kW unit, up to 5 kW per phase. This is a practical advantage in older homes with large single-phase loads (such as water heaters or single-phase appliances).
Due to the 20 kVA power draw from the grid, the storage unit can be quickly charged during off-peak hours under dynamic or two-rate pricing structures.
How does it work?
The inverter manages three independent MPPT trackers, with one string per MPPT, for a total PV input of up to 20 kW. The input voltage is rated up to 1,000 V, the operating range is 80–950 V, the feed-in starts at 100 V, and the nominal PV input voltage is 750 V. An input current of 20 A and a short-circuit current of 30 A are allowed per MPPT.
The 80–950 V operating range and the 100 V feed-in threshold offer the greatest design flexibility in this category: even short strings of 4–6 modules can operate, meaning that even small areas on complex roofs are not excluded. The 20 kW PV input allows for a DC/AC ratio of 2.0 compared to 10 kW AC, which, under Hungarian conditions, provides longer periods of full-power operation in the morning and late afternoon.
The battery side accepts a voltage range of 120–750 V, with a nominal voltage of 600 V, and features CAN communication with the BMS. Maximum charge and discharge currents are 40/40 A, maximum charge power is 15 kW, and maximum discharge power is 11 kW. The discharge power is therefore greater than the nominal AC output, providing a reserve for handling peak loads.
In the event of a power outage, the switchover occurs in less than 10 ms. The backup port continuously delivers 10 kVA and can handle a peak of 18 kVA (26.1 A) for one minute. In island mode, the THDv remains below 3% under linear loads.
It also includes two features that simplify commissioning. The CT phase sequence self-correction ensures that swapped current transformers do not cause measurement errors; the system corrects this automatically. Remote parameterization means that on-site visits are not required for subsequent adjustments.
Technical and System-Level Benefits
AC side: 400/380 V, 3L/N/PE, 50/60 Hz. Nominal and maximum apparent power supplied to the grid: 10,000 VA; nominal and maximum output current: 15.2 A; maximum grid-side current: 26.1 A; THDi <3%; power factor adjustable between 0.8 leading and 0.8 lagging.
Efficiency: max. 98.2%, European efficiency 97.6%. This is a strong figure in this category, resulting in measurable annual yield benefits on a 20 kWp rooftop system.
Protection: islanding protection, PV insulation resistance measurement, PV polarity protection, battery polarity protection, built-in residual current monitoring unit (RCMU), AC overcurrent and overvoltage protection, PV DC disconnect, and DC Type II and AC Type III surge arresters.
Communication and integration: CAN to the battery BMS, RS485 to the EMS (Modbus) and external meter, Modbus TCP/RTU and SunSpec protocols, and Wi-Fi and LAN to the cloud. It also features RCR/DRED input, remote shutdown input, and dry-point output. Display options include LED and LCD, plus a mobile app.
Thanks to the RCR/DRED input and high-precision zero-feed control, it can be installed even at sites where the grid permit stipulates limited or zero feed-in.
Operating temperature range: −30 to +60 °C; humidity: 0–100%; can be installed at altitudes up to 3,000 m. Cooling via an intelligent fan system, with a noise level below 40 dB. Weight: 27.2 kg; dimensions: 500 × 585 × 212 mm; wall-mounted design; IP66 protection rating.
Compliance: EN 50549-1, CEI 0-21, AS 4777.2, UNE 217001, UNE 2170002, NTS Type A, IEC/EN 62109-1&2, EMC IEC/EN 61000-6-1/2/3/4.
Compatible products from the SOLARKIT lineup:Stack 280 battery module,Stack 280 BDU and base,Stack 314 battery module,SBDU300-Heat BDU and base.
Differences
There are six power levels within the HT-A series, and the choice depends on two parameters: the PV input and the number of MPPTs.
5 kW (D5K-HT-A): 10 kW PV, 2 MPPTs, 7.5/5 kW battery charge/discharge, 98.0% efficiency.
6 kW: 12 kW PV, 2 MPPT, 9/6.6 kW, 98.1%.
8 kW: 16 kW PV, 2 MPPTs, 12/8.8 kW, 98.1%.
10 kW (this product): 20 kW PV, 3 MPPT, 15/11 kW, 98.2%.
12 kW: 24 kW PV, 3 MPPT, 18/13.2 kW, 98.2%.
15 kW: 30 kW PV, 3 MPPT, 22.5/16.5 kW, 98.2%.
The 10 kW model is the point where the series transitions to a third MPPT and higher efficiency. The 8 kW model still has only two MPPTs, so if the roof has three orientations, the 10 kW model is the smallest version capable of handling this. This is often a more important decision factor than the power output itself.
The housing, weight (27.2 kg), dimensions, and IP66 rating are identical across the entire series; only the 12- and 15-kW models have a higher noise level (below 45 dB instead of 40 dB). The installation effort is therefore the same, and upgrading does not entail higher installation costs.
Choose the 10 kW unit over the 8 kW model if your roof has a capacity of more than 16 kWp, or if you need to manage more than three different orientations. Opt for the 12 kW model if your roof has a capacity greater than 20 kWp.
Important to Know
The inverter does not function as a storage system on its own: it requires a 120–750 V, 600 V nominal high-voltage battery with CAN communication. The compatible battery type and maximum capacity are specified in the Dyness compatibility list and the installation guide; these must be verified when placing an order.
It is important to note that this is an HV inverter. 48 V LV batteries, such as the Powerbox G2, are not compatible with it. If the customer has an LV storage system or plans to install one, a different inverter series is required.
The maximum 11 kW discharge power is limited by the inverter. Actual discharge power is also limited by the battery’s capacity, so the system must be sized on the battery side as well; simply selecting the inverter is not sufficient.
The 18 kVA one-minute peak power is not a continuous value. When sizing for peak load, calculate using the 10 kVA continuous backup power.
Each phase can be loaded asymmetrically up to 50% of the nominal power; for this model, that means up to 5 kW per phase. This must be verified for large single-phase loads.
It features fan-assisted cooling. This provides better performance under heavy loads, but it involves moving parts and dust accumulation; therefore, in dusty environments—such as workshops or agricultural buildings—the ventilation openings must be inspected periodically.
SOLARKIT Reviews
This inverter excels where design flexibility is required. The 80–950 V MPPT range and the 100 V input threshold are the most accommodating currently available: even short strings work, so on complex Hungarian tile roofs, there’s no need to skip sections or force connections. The 2.0 DC/AC ratio means that up to 20 kWp can be connected to a 10 kW unit, which provides a measurable boost during the morning and afternoon hours.
The CT phase sequence self-correction is an underappreciated benefit for installers. Reversed or swapped connections of the inverters are the most common commissioning errors, and this feature eliminates them from the system. Additionally, remote parameterization saves an average of one return service call per project, which represents a tangible cost savings on the B2B side.
The 27.2 kg wall-mounted model can be installed by a single person, and the 15 kW model uses the same enclosure, so the installer learns one machine type and works with it across the entire power range. From a reseller’s perspective, this means a flatter learning curve and fewer opportunities for error.
In your proposal, highlight two key features: the three MPPT trackers and the 20 kW PV input. These two specifications are what deliver more generated kWh at most sites compared to competitors—not the efficiency rating, which every manufacturer advertises as around 98%.
If the customer’s roof is under 16 kWp and has two orientations, the 8 kW system is sufficient and offers better value for money. If the roof has three orientations or is over 16 kWp, the 10 kW system is the right choice. And for anything over 20 kWp, go straight for the 12 kW system, because the PV input limit cannot be upgraded later.